Category: FAA Regulation – Operational Safety
Title: Holdover Time (HOT) Guidelines 2025–2026
Date of Issue: 12 August 2025
Applicability: CAT & NCC Operators, Ground De/Anti-Icing Personnel
Summary of Change
Winter is around the corner — and with it comes the challenge of safe ground de/anti-icing operations.
On 12 August 2025, the FAA released the updated Holdover Time (HOT) Guidelines for the 2025–2026 season. These guidelines remain the industry’s key reference for determining safe de/anti-icing holdover and allowance times. This year’s edition introduces six new fluid-specific tables, revised generic values, new precipitation categories, and updated allowance times, along with several editorial clarifications.
Impact on Operators
- New fluid-specific HOT tables have been added for six fluids: ESSPO Nordwing PG2 (Type II), AFLRUS Green Flo Type IV, AllClear Clear IV Flight, ESSPO Nordwing PG4, Newave FCY-EGIV PLUS, and Xinjiang Clearice-IV. These must be incorporated into operational procedures and ground staff references.
- Extended cold weather testing (< –14 °C) now provides fluid-specific HOTs for three existing fluids (COREICEPHOB Type II, PROFLIGHT EG4, PROFLIGHT PG4), ensuring safer planning in very cold snow conditions.
- Removed dilutions: The 75/25 and 50/50 dilutions for Newave FCY-2 (Type II) are no longer valid and should be deleted from manuals.
- Generic adjustments:
- Type II generics: several HOT values increased following removal of fluid data.
- Type IV generics: several HOT values decreased due to inclusion of new fluids with shorter times.
- Precipitation category expansion:
- Type I (aluminum & composite): HOT values for Snow mixed with Freezing Fog increased.
- A new column for Moderate Snow mixed with Rain has been added across all Type I–IV fluid-specific tables.
- Allowance time changes:
- Validation table for Type III & IV fluids updated.
- Increases for Moderate Ice Pellets mixed with Moderate Snow.
- Additional references for ice pellets mixed with drizzle/freezing drizzle.
- Clarified guidance for small hail in METAR reports.
- Editorial clarifications throughout tables (temperature references, note structures) for better operational clarity.
Affected Manuals
- Operations Manual – HOT references and de/anti-icing procedures.
- Ground Ops Manual – Integration of new fluid-specific tables, allowance time validations, and staff briefings.
TRS Recommendation
Operators should:
- Review and integrate the updated FAA HOT Guidelines before winter operations commence.
- Remove outdated dilution references and adjust procedures for revised HOT values.
- Update all relevant manuals, checklists, and training materials.
- Train both flight and ground personnel on new fluid-specific data, cold-weather updates, and expanded precipitation categories.
TRS supports clients in:
- Updating manuals and documentation in line with FAA HOT 2025–2026.
- Ensuring compliance through readiness checks before the season begins.
Official Reference
FAA Holdover Time Guidelines – Winter 2025–2026
Further Information
Download FAA HOT Guidelines – Winter 2025–2026 (PDF)
Visit FAA’s Aircraft Ground Deicing Resources